Skip to content
Snippets Groups Projects
Commit 29b7190b authored by Rolf Niepraschk's avatar Rolf Niepraschk
Browse files

Testversion zu Kalibriergebührenlisten

parent c6f1a82c
No related branches found
No related tags found
No related merge requests found
......@@ -3,7 +3,7 @@
\setcounter{errorcontextlines}{100} \listfiles
\NeedsTeXFormat{LaTeX2e}[1999/12/01]
\ProvidesClass{pt-declaration}
\ProvidesClass{ptp-declaration}
[2016/10/17 v0.1b PTB-Klasse (RN)]
\newcommand*\vl@lang{main=ngerman}
......
File added
%---------------------------
\setcounter{errorcontextlines}{100}
\listfiles
\documentclass[fontsize=11pt,paper=a4,pagesize]{scrartcl}
\usepackage[top=20mm,bottom=30mm,left=15mm,right=15mm]{geometry}
\usepackage[utf8]{inputenc}
\usepackage[T1]{fontenc}
\usepackage[ngerman]{babel}
\usepackage{textcomp}
\usepackage{tgheros}
\usepackage{xltabular,booktabs,ragged2e,calc,siunitx-PTB}
\usepackage{eurosym}
\let\texteuro=\officialeuro
\renewcommand\familydefault{\sfdefault}
\newdimen\numwidth
\setlength\numwidth{\widthof{9999.99}}
\newcolumntype{L}{>{\RaggedRight\arraybackslash}X}
\newcolumntype{V}{>{\hspace{\numwidth}\rlap\bgroup}c<{\egroup}}
\newcommand*\marker{\quad\textbullet~}
\pagestyle{empty}
\begin{document}
\begin{center} \usekomafont{disposition}\Large
Physikalisch-Technische Bundesanstalt \\[.1\baselineskip]
Vakuummetrologie \\[.5\baselineskip]
Kalibriergebühren \par
\end{center}
\begin{xltabular}[l]{\textwidth}{@{}cLV@{}}
\toprule
\multicolumn{1}{@{}c}{\textbf{Nr.}} &
\multicolumn{1}{c}{\textbf{Kalibrierobjekt}} &
\multicolumn{1}{c@{}}{\textbf{Gebühr in €}} \\
\toprule
\endhead
1 &
Ionisationsvakuummeter ausgeheizt, Grundgebühr, zwei Dekaden &
\num{1969.00} \\
&
Ionisationsvakuummeter nicht ausgeheizt, Grundgebühr, zwei Dekaden &
\num{1700.00} \\
&
\marker zusätzliche Dekade &
\num{447.50} \\
&
\marker zusätzliche Dekade unter \SI{1e-10}{\mbar} &
\num{581.75} \\
&
\marker zusätzliche Dekade über \SI{1e-4}{\mbar} &
\num{402.75} \\
&
\marker zusätzliches Gas, zwei Dekaden &
\num{1118.75} \\
\midrule
2 &
Gasreibungsvakuummeter, Sigma (effektiv), Grundgebühr &
\num{1476.75} \\
&
\marker Sigma (effektiv), je zusätzliches Gas &
\num{537,00 } \\
\midrule
3 &
Membranvakuummeter, FS \SI{0.01}{\torr}, zwei Dekaden, fünf Punkte je Dekade,
Grundgebühr &
\num{1655.75} \\
&
Membranvakuummeter, FS \SI{0.1}{\torr}, \SI{0.25}{\torr}, zwei Dekaden, fünf
Punkte je Dekade, Grundgebühr &
\num{1432.00} \\
&
\marker FS \SI{0.1}{\torr}, \SI{0.25}{\torr} je zusätzliches Gas, zwei Dekaden &
\num{716.00} \\
&
\marker FS \SI{0.1}{\torr}, \SI{0.25}{\torr}, zusätzliche Dekade &
\num{358.00} \\
&
Membranvakuummeter, FS \SI{1}{\torr}, \SI{10}{\torr}, zwei Dekaden, Grundgebühr
& \num{1253.00} \\
&
\marker FS \SI{1}{\torr}, \SI{10}{\torr}, je zusätzliches Gas, zwei Dekaden &
\num{537.00} \\
&
\marker FS \SI{1}{\torr}, \SI{10}{\torr}, zusätzliche Dekade &
\num{313.25} \\
&
Membranvakuummeter, FS \SI{100}{\torr}, \SI{1000}{\torr}, drei Dekaden,
Grundgebühr & \num{1521.50} \\
&
\marker FS \SI{100}{\torr}, \SI{1000}{\torr}, je zusätzliches Gas, drei Dekaden &
\num{850.25} \\
&
\marker FS \SI{100}{\torr}, \SI{1000}{\torr}, zusätzliche Dekade &
\num{268.50} \\
&
\marker \SI{1}{\torr}, \SIrange{30}{130}{\Pa} mit FRS5 zusätzlich zur
Grundgebühr & \num{402.75} \\
&
\marker \SI{10}{\torr}, \SIrange{30}{1300}{\Pa} mit FRS5 zusätzlich zur
Grundgebühr & \num{626.50} \\
&
\marker \SI{100}{\torr}, \SIrange{30}{10000}{\Pa} mit FRS5 zusätzlich zur
Grundgebühr & \num{805.50} \\
\midrule
4 &
Testleck (gegen Vakuum), Grundgebühr &
\num{1432.00} \\
&
\marker je zusätzliche Temperatur oder zusätzlicher Druck &
\num{895.00} \\
&
\marker Gasfluss unter \SI{1e-9}{\mbar\litre\per\second}, Zusatzgebühr &
\num{895.00} \\
&
Testleck (gegen Atmosphäre), Grundgebühr &
\num{895.00} \\
&
\marker je zusätzliche Temperatur oder zusätzlicher Druck &
\num{358.00} \\
&
Testleck (gegen Atmosphäre), Leckelement mit Druckeinstellung und Messung &
\num{1432.00} \\
\bottomrule
\end{xltabular}
\end{document}
%---------------------------
File added
%---------------------------
\setcounter{errorcontextlines}{100}
\listfiles
\documentclass[fontsize=11pt,paper=a4,pagesize]{scrartcl}
\usepackage[top=20mm,bottom=30mm,left=15mm,right=15mm]{geometry}
\usepackage[utf8]{inputenc}
\usepackage[T1]{fontenc}
\usepackage[english]{babel}
\usepackage{textcomp}
\usepackage{tgheros}
\usepackage{xltabular,booktabs,ragged2e,calc,siunitx-PTB}
\usepackage{eurosym}
\let\texteuro=\officialeuro
\renewcommand\familydefault{\sfdefault}
\newdimen\numwidth
\setlength\numwidth{\widthof{9999.99}}
\newcolumntype{L}{>{\RaggedRight\arraybackslash}X}
\newcolumntype{V}{>{\hspace{\numwidth}\rlap\bgroup}c<{\egroup}}
\newcommand*\marker{\quad\textbullet~}
\pagestyle{empty}
\begin{document}
\begin{center} \usekomafont{disposition}\Large
Physikalisch-Technische Bundesanstalt \\[.1\baselineskip]
Vacuum Metrology \\[.5\baselineskip]
Fees for Calibrations \par
\end{center}
\begin{xltabular}[l]{\textwidth}{@{}cLV@{}}
\toprule
\multicolumn{1}{@{}c}{\textbf{No.}} &
\multicolumn{1}{c}{\textbf{Calibration device}} &
\multicolumn{1}{c@{}}{\textbf{Fee in €}} \\
\toprule
\endhead
1 &
Ionisation gauge baked out, basic fee, two decades &
\num{1969.00} \\
&
Ionisation gauge not baked out, basic fee, two decades &
\num{1700.00} \\
&
\marker additional decade &
\num{447.50} \\
&
\marker additional decade under \SI{1e-10}{\mbar} &
\num{581.75} \\
&
\marker additional decade over \SI{1e-4}{\mbar} &
\num{402.75} \\
&
\marker additional gas, two decades &
\num{1118.75} \\
\midrule
2 &
Spinning rotor gauge, Sigma (effective), basic fee &
\num{1476.75} \\
&
\marker Sigma (effective), each additional gas &
\num{537,00 } \\
\midrule
3 &
Capacitance diaphragm gauge , FS \SI{0.01}{\torr}, two decades, five points
each decade, basic fee &
\num{1655.75} \\
&
Capacitance diaphragm gauge , FS \SI{0.1}{\torr}, \SI{0.25}{\torr}, two
decades, five points each decade, basic fee &
\num{1432.00} \\
&
\marker FS \SI{0.1}{\torr}, \SI{0.25}{\torr} each additional gas, two decades &
\num{716.00} \\
&
\marker FS \SI{0.1}{\torr}, \SI{0.25}{\torr}, additional decade &
\num{358.00} \\
&
Capacitance diaphragm gauge , FS \SI{1}{\torr}, \SI{10}{\torr}, two decades,
basic fee
& \num{1253.00} \\
&
\marker FS \SI{1}{\torr}, \SI{10}{\torr}, each additional gas, two decades &
\num{537.00} \\
&
\marker FS \SI{1}{\torr}, \SI{10}{\torr}, additional decade &
\num{313.25} \\
&
Capacitance diaphragm gauge , FS \SI{100}{\torr}, \SI{1000}{\torr}, three
decades, basic fee & \num{1521.50} \\
&
\marker FS \SI{100}{\torr}, \SI{1000}{\torr}, each additional gas, three
decades & \num{850.25} \\
&
\marker FS \SI{100}{\torr}, \SI{1000}{\torr}, additional decade &
\num{268.50} \\
&
\marker \SI{1}{\torr}, \SIrange{30}{130}{\Pa} with FRS5 in addition to
basic fee & \num{402.75} \\
&
\marker \SI{10}{\torr}, \SIrange{30}{1300}{\Pa} with FRS5 in addition to
basic fee & \num{626.50} \\
&
\marker \SI{100}{\torr}, \SIrange{30}{10000}{\Pa} with FRS5 in addition to
basic fee & \num{805.50} \\
\midrule
4 &
Test leak (against vacuum), basic fee &
\num{1432.00} \\
&
\marker each additional temperature or additional pressure &
\num{895.00} \\
&
\marker gas flow under \SI{1e-9}{\mbar\litre\per\second}, additional fee &
\num{895.00} \\
&
Test leak (against atmosphere), basic fee &
\num{895.00} \\
&
\marker each additional temperature or additional pressure &
\num{358.00} \\
&
Test leak (against atmosphere), Leckelement ??? with pressure setting and measuring &
\num{1432.00} \\
\bottomrule
\end{xltabular}
\end{document}
%---------------------------
0% Loading or .
You are about to add 0 people to the discussion. Proceed with caution.
Finish editing this message first!
Please register or to comment