Newer
Older
\ProvidesFile{KK-2015.clo}[2015/12/10 v1.0c class option (RN/PTB)]
\iffalse
Definitionen, die ab Januar 2015 gültig sind.
\fi
\RequirePackage[%
headheight=44bp,
marginparwidth=0pt,
left=69bp,
right=40bp,
textheight=609bp,
top=164bp,
headsep=77bp,
footskip=0bp,
]{geometry}
\newcommand*\ks@printFirstPage{%
\unitlength=1bp %
\AtPageLowerLeft{%
%------------- Kopf ------------
%%%\put(69,783){\parbox{\textwidth}{\huge\bfseries\ks@PTB}}
%%%\put(69,760){\parbox{\textwidth}{\large\bfseries\ks@BSuB}}
\put(68,754){\includegraphics[width=308bp]{PTB-logo-2015.pdf}}
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
\put(287,680){\includegraphics[width=62bp]{Adler.pdf}}
\put(252,640){\normalfont\huge Kalibrierschein}
\put(260,622){\normalfont\itshape\large Calibration Certificate}
%-----------Mittelteil ---------
\ks@put@main
%------------- Fuss ------------
%%%\put(-18bp,38bp){\rotatebox{90}{\xscriptsize 391~00B~k}}
%%%\put(62,83){\linethickness{1.3bp}\line(1,0){506}}
\normalfont\scriptsize
\put(68,68){\parbox[t]{\textwidth}{%
Kalibrierscheine ohne Unterschrift und Siegel haben keine G\"ultigkeit.
Dieser Kalibrierschein darf nur unver\"andert weiterverbreitet\\
werden. Ausz\"uge bed\"urfen der Genehmigung der
Physikalisch-Technischen Bundesanstalt. \\
\normalfont\itshape
Calibration certificates without signature and seal are not valid.
This calibration certificate may not be reproduced other than in
full. \\ Extracts may be taken only with permission of the
Physikalisch-Technische Bundesanstalt.
}}
}
}
\newcommand\ks@put@main{%
\normalfont\normalsize
\@tempdima=68bp %
\@tempdimb=648bp %
\@tempdimd=207bp %
%--------------------------------
\advance\@tempdimb-60bp %
\@tempdimc=\@tempdimb \advance\@tempdimc-10bp %
\put(\@tempdima,\@tempdimb){Gegenstand:}
\put(\@tempdimd,\@tempdimb){\ks@object}
\put(\@tempdima,\@tempdimc){\scriptsize\itshape Object:}
%--------------------------------
\advance\@tempdimb-60bp %
\@tempdimc=\@tempdimb \advance\@tempdimc-10bp %
\put(\@tempdima,\@tempdimb){Hersteller:}
\put(\@tempdimd,\@tempdimb){\ks@printDevicesTable{348bp}{46bp}{29bp}}
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
\put(\@tempdima,\@tempdimc){\scriptsize\itshape Manufacturer:}
%--------------------------------
\advance\@tempdimb-60bp %
\@tempdimc=\@tempdimb \advance\@tempdimc-10bp %
\put(\@tempdima,\@tempdimb){Typ:}
\put(\@tempdima,\@tempdimc){\scriptsize\itshape Type:}
%--------------------------------
%%%\@tempdimb=478bp %
\@tempdimb=455bp %
%--------------------------------
\advance\@tempdimb-30bp %
\@tempdimc=\@tempdimb \advance\@tempdimc-10bp %
\put(\@tempdima,\@tempdimb){Kennnummer:}
\put(\@tempdima,\@tempdimc){\scriptsize\itshape Serial No.:}
%--------------------------------
\advance\@tempdimb-30bp %
\@tempdimc=\@tempdimb \advance\@tempdimc-10bp %
\put(\@tempdima,\@tempdimb){Auftraggeber:}
\put(\@tempdimd,\@tempdimb){\ks@applicant@table}
\put(\@tempdima,\@tempdimc){\scriptsize\itshape Applicant:}
\@tempdimb=377bp %
%--------------------------------
\advance\@tempdimb-53bp %
\@tempdimc=\@tempdimb \advance\@tempdimc-10bp %
\put(\@tempdima,\@tempdimb){Anzahl der Seiten:}
\put(\@tempdimd,\@tempdimb){\ztotpages}
\put(\@tempdima,\@tempdimc){\scriptsize\itshape Number of pages:}
%--------------------------------
\advance\@tempdimb-30bp %
\@tempdimc=\@tempdimb \advance\@tempdimc-10bp %
\put(\@tempdima,\@tempdimb){Gesch\"aftszeichen:}
\put(\@tempdimd,\@tempdimb){\ks@refNo}
\put(\@tempdima,\@tempdimc){\scriptsize\itshape Reference No.:}
%--------------------------------
\advance\@tempdimb-30bp %
\@tempdimc=\@tempdimb \advance\@tempdimc-10bp %
\put(\@tempdima,\@tempdimb){Kalibrierzeichen:}
\put(\@tempdimd,\@tempdimb){\ks@calibMark}
\put(\@tempdima,\@tempdimc){\scriptsize\itshape Calibration mark:}
%--------------------------------
\advance\@tempdimb-30bp %
\@tempdimc=\@tempdimb \advance\@tempdimc-10bp %
\put(\@tempdima,\@tempdimb){Datum der Kalibrierung:}
\put(\@tempdimd,\@tempdimb){\ks@calibDate}
\put(\@tempdima,\@tempdimc){\scriptsize\itshape Date of calibration:}
%--------------------------------
\@tempdime=\@tempdimd \advance\@tempdime185bp %
\advance\@tempdimb-30bp %
%%%\@tempdimb=204bp %
\@tempdimc=\@tempdimb \advance\@tempdimc-10bp %
\put(\@tempdima,\@tempdimb){Im Auftrag}
\put(\@tempdima,\@tempdimc){\scriptsize\itshape On behalf of PTB}
\put(\@tempdimd,\@tempdimb){\ks@location, \ks@certificateDate}
\put(\@tempdime,\@tempdimb){Im Auftrag}
\put(\@tempdime,\@tempdimc){\scriptsize\itshape On behalf of PTB}
\advance\@tempdimb-24bp %
\@tempdimc=\@tempdimb \advance\@tempdimc-10bp %
\put(\@tempdimd,\@tempdimb){Siegel}
\put(\@tempdimd,\@tempdimc){\scriptsize\itshape Seal}
%--------------------------------
\advance\@tempdimb-40bp %
\put(\@tempdima,\@tempdimb){\ks@byOrder}
\put(\@tempdime,\@tempdimb){\ks@examiner}
%--------------------------------
\put(46bp,178bp){\rotatebox[origin=c]{90}{\tiny 391~00B~n}}
}
\newcommand*\ks@head{%
\begin{picture}(0,0)
\unitlength=1bp %
%%%\put(-1,28){\parbox{\textwidth}{\normalfont\huge\bfseries\ks@PTB}}
\put(-1,-5){\includegraphics[width=308bp]{PTB-logo-2015.pdf}}
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
\put(-1,-35){\parbox{\textwidth}{%
\normalfont\small
Seite~\thepage\ zum Kalibrierschein vom~\ks@certificateDate,
Kalibrierzeichen:~\ks@calibMark \\
\scriptsize\itshape
Page~\thepage\ of the Calibration Certificate dated~\ks@certificateDate,
calibration mark:~\ks@calibMark
}}
\end{picture}
}
\newcommand\ks@lastPage{%
\large
\begin{otherlanguage}{ngerman}
\textbf{\Large Die Physikalisch-Technische Bundesanstalt} (PTB) in
Braunschweig und Berlin ist das nationale Metrologieinstitut und die
technische Oberbeh\"orde der Bundesrepublik Deutschland f\"ur das
Messwesen. Die PTB geh\"ort zum Gesch\"aftsbereich des Bundesministeriums
f\"ur Wirtschaft und Energie. Sie erf\"ullt die Anforderungen an Kalibrier-
und Pr\"uflaboratorien auf der Grundlage der DIN EN ISO/IEC 17025.
Zentrale Aufgabe der PTB ist es, die gesetzlichen Einheiten in
\"Ubereinstimmung mit dem Internationalen Einheitensystem (SI) darzustellen,
zu bewahren und weiterzugeben. Die PTB steht damit an oberster Stelle der
metrologischen Hierarchie in Deutschland. Die Kalibrierscheine der PTB
dokumentieren eine auf nationale Normale r\"uckgef\"uhrte Kalibrierung.
Dieser Ergebnisbericht ist in \"Ubereinstimmung mit den Kalibrier- und
Messm\"oglichkeiten (CMCs), wie sie im Anhang~C des gegenseitigen
Abkommens (MRA) des Internationalen Komitees f\"ur Ma\ss e und
Gewichte enthalten sind. Im Rahmen des MRA wird die G\"ultigkeit der
Ergebnisberichte von allen teilnehmenden Instituten f\"ur die im
Anhang~C spezifizierten Messgr\"o\ss en, Messbereiche und
Messunsicherheiten gegenseitig anerkannt (n\"ahere Informationen unter
http://www.bipm.org).
\end{otherlanguage}
\begingroup
\vspace{1.6\baselineskip}
\centering
\includegraphics[width=68bp]{CIPM-MRA.png}\par
\vspace{1.6\baselineskip}
\endgroup
\itshape
\begin{otherlanguage}{english}
\textbf{\Large The Physikalisch-Technische Bundesanstalt} (PTB) in
Braunschweig and Berlin is the National Metrology Institute and the
supreme technical authority of the Federal Republic of Germany for metrology.
The PTB comes under the auspices of the Federal Ministry of Economics and
Energy. It meets the requirements for calibration and testing laboratories as
defined in DIN EN ISO/IEC 17025.
The central task of PTB is to realize, to maintain and to disseminate the
legal units in compliance with the International System of Units (SI). PTB
thus is at the top of the metrological hierarchy in Germany. The calibration
certificates issued by PTB document a calibration traceable to national
measurement standards.
This certificate is consistent with the Calibration and Measurement
Capabilities (CMCs) that are included in Appendix~C of the Mutual
Recognition Arrangement (MRA) drawn up by the International Committee for
Weights and Measures (CIPM). Under the MRA, all participating institutes
recognize the validity of each other’s calibration and measurement
certificates for the quantities, ranges and measurement uncertainties
specified in Appendix~C (for details, see http://www.bipm.org).
\end{otherlanguage}
\vfill \mbox{}
}
\newcommand*\ks@@foot{%
\begin{picture}(0,0)
\unitlength=1bp %
%%%\put(-7,23){\linethickness{1.3bp}\line(1,0){506}}
\normalfont\small
\put(-1,9){Physikalisch-Technische Bundesanstalt}
\scriptsize
\put(-1,-3){\parbox[t]{.25\textwidth}{%
Bundesallee 100 \\
38116 Braunschweig \\
DEUTSCHLAND
}}
\put(280,-3){\parbox[t]{.25\textwidth}{%
Abbestra\ss e 2--12 \\
10587 Berlin \\
DEUTSCHLAND
}}
\end{picture}
}
\endinput
%%
%% End of file `KK-2015.clo'.