diff --git a/templates/latex/device_description-tla/de-heading.tex b/templates/latex/device_description-tla/de-heading.tex
new file mode 100644
index 0000000000000000000000000000000000000000..934181b0d1bb97e78e4cffd5bdb214d0468f899f
--- /dev/null
+++ b/templates/latex/device_description-tla/de-heading.tex
@@ -0,0 +1,2 @@
+\Section{Beschreibung zum Kalibriergerät}{Description relating to calibration device}
+
diff --git a/templates/latex/device_description-tla/de-para_0-alt_0-device_description.tex b/templates/latex/device_description-tla/de-para_0-alt_0-device_description.tex
new file mode 100644
index 0000000000000000000000000000000000000000..1fcb46a7f281c0bed7a73f6e001545b7b519ec69
--- /dev/null
+++ b/templates/latex/device_description-tla/de-para_0-alt_0-device_description.tex
@@ -0,0 +1,11 @@
+((*set lastcert = Meta["last_cert"]*))
+((* set f = Formula[0] *))
+((* set PressureUpstream = f.PressureUpstream|default('99999') *))
+Das Testleck hat einen Gasvorrat mit Druckanzeige. Der Fülldruck des Testlecks betrug zum Zeitpunkt der Messung (((PressureUpstream)))~ bar.
+((*if lastcert*))Die von der PTB zuletzt durchgeführte Kalibrierung ist im 
+Kalibrierschein (((lastcert))) beschrieben.((*endif*))
+
+\begin{english}
+  The helium leak has a gas reservoir with a pressure indication. The filling pressure at the time of measurements was (((PressureUpstream)))~ bar. 
+  ((*if lastcert*))The previous calibration performed by PTB is described in the calibration certificate (((lastcert))).((*endif*))
+\end{english}
diff --git a/templates/latex/device_description-tla/en-heading.tex b/templates/latex/device_description-tla/en-heading.tex
new file mode 100644
index 0000000000000000000000000000000000000000..2af09be2c1229dfdd8281a675c798929a8f94aec
--- /dev/null
+++ b/templates/latex/device_description-tla/en-heading.tex
@@ -0,0 +1 @@
+\section{Description relating to calibration device}
diff --git a/templates/latex/device_description-tla/en-para_0-alt_0-device_description.tex b/templates/latex/device_description-tla/en-para_0-alt_0-device_description.tex
new file mode 100644
index 0000000000000000000000000000000000000000..2ed33ba12137bb1b7e29b8c6a9f4f1c763ca6c8f
--- /dev/null
+++ b/templates/latex/device_description-tla/en-para_0-alt_0-device_description.tex
@@ -0,0 +1,5 @@
+((*set lastcert = Meta["last_cert"]*))
+((* set f = Formula[0] *))
+((* set PressureUpstream = f.PressureUpstream|default('99999') *))
+The helium leak has a gas reservoir with a pressure indication. The filling pressure at the time of measurements was (((PressureUpstream)))~ bar. ((*if lastcert*))The previous calibration performed by PTB is 
+described in the calibration certificate (((lastcert))).((*endif*))
diff --git a/templates/latex/measurement_results-fm1-tlv/en-para_0-alt_0-results.tex b/templates/latex/measurement_results-fm1-tlv/en-para_0-alt_0-results.tex
index 6a1976470a46a96fd751f77eb897ffad7e8ed9e3..b84e39000c545afdb976c860e3c8d85eb9a72e16 100644
--- a/templates/latex/measurement_results-fm1-tlv/en-para_0-alt_0-results.tex
+++ b/templates/latex/measurement_results-fm1-tlv/en-para_0-alt_0-results.tex
@@ -33,8 +33,5 @@ and at a chamber temperature
 \( \vartheta_\text{Ch}=\SI{(((TemperatureTLx)))}{\degreeCelsius} \) 
 the leak rate \( q_{pV}(\SI{(((TemperatureTLx)))}{\degreeCelsius}) \) will be:
 
-\[ q_{pV}(\SI{(((TemperatureTLx)))}{\degreeCelsius}) = \SI{(((FlowpV2x)))} 
-{\mbar\litre\per\second} \]   
-
 The relative uncertainty \( U \) of the stated leak rate is 
 \( \SI{(((LeakUncertainty)))}{\percent} \).