From 38d043ac4b8591166b88c264cd511360c175bdf3 Mon Sep 17 00:00:00 2001 From: Matthias Bernien <bernie01@pad.ptb.de> Date: Thu, 23 Jan 2025 13:06:06 +0100 Subject: [PATCH] English version for gauge sensitivity --- templates/latex/result_sens/en-heading.tex | 1 + templates/latex/result_sens/en-para_0-alt_0-result.tex | 8 ++++++++ templates/latex/sens/en-heading.tex | 1 + templates/latex/sens/en-para_0-alt_0-sigma.tex | 7 +++++++ 4 files changed, 17 insertions(+) create mode 100644 templates/latex/result_sens/en-heading.tex create mode 100644 templates/latex/result_sens/en-para_0-alt_0-result.tex create mode 100644 templates/latex/sens/en-heading.tex create mode 100644 templates/latex/sens/en-para_0-alt_0-sigma.tex diff --git a/templates/latex/result_sens/en-heading.tex b/templates/latex/result_sens/en-heading.tex new file mode 100644 index 0000000..e7b760b --- /dev/null +++ b/templates/latex/result_sens/en-heading.tex @@ -0,0 +1 @@ +\section{Result of the calibration} diff --git a/templates/latex/result_sens/en-para_0-alt_0-result.tex b/templates/latex/result_sens/en-para_0-alt_0-result.tex new file mode 100644 index 0000000..ef71491 --- /dev/null +++ b/templates/latex/result_sens/en-para_0-alt_0-result.tex @@ -0,0 +1,8 @@ +The results of the measurements are given in the following table. +\(U(S)/S\) is the uncertainty of the expanded relative measurement uncertainty +with coverage factor \(k = 2\) at the time of calibration. Included is the repeatability of the measurement under +otherwise identical conditions (\(p_\text{cal}, T\)). + +(((Device.Text.uncertainty))) + +\printResultTable diff --git a/templates/latex/sens/en-heading.tex b/templates/latex/sens/en-heading.tex new file mode 100644 index 0000000..8444a36 --- /dev/null +++ b/templates/latex/sens/en-heading.tex @@ -0,0 +1 @@ +\section{Gauge sensitivity} diff --git a/templates/latex/sens/en-para_0-alt_0-sigma.tex b/templates/latex/sens/en-para_0-alt_0-sigma.tex new file mode 100644 index 0000000..f10eb87 --- /dev/null +++ b/templates/latex/sens/en-para_0-alt_0-sigma.tex @@ -0,0 +1,7 @@ +The gauge sensitivity \(S\) was calculated according to: +\[S = \frac{i_\text{c} - i_\text{r}}{i_\text{e}\,p_\text{cal}}\] +with \(i_\text{c}\) the collector current at calibration pressure \(p_\text{cal}\), \(i_\text{r}\) the collector current +at residual pressure and \(i_\text{e}\) the emmission current. The gauge sensitivity during use \(S(T_\text{ch})\) is obtained +from the gas temperature \(T_\text{ch}\) (in kelvins) +via: \[S(T_\text{ch}) = S(T_0)\frac{T_0}{T_\text{ch}}\] +with \(T_0\) the gas temperature during calibration. -- GitLab